XCM-32
Motion control XCM series
1. Specification

Special PLC for motion control
Invoke G code directly in XCP Pro software
Larger capacity and higher processing speed
Can be connected with expansion module and BD board, support MODBUS

Functional Specification

Item
Specification
Program Operation Mode
Circulation scanning mode, timing scanning mode
Program Mode
Instructions and ladder chart
Dispose Speed
0.5us
Power Failure Holding
FlashROM
User Program's Capacity
8000 steps (24K Steps in protective download)
I/O Points
18 input points,14 output points
Interior Coil's Points (M)
8000 points
Step
1024 points
 
Timer (T)
Points
620 points
Specification
100mS timer:set time 0.1~3276.7 seconds
10mS timer:set time 0.01~327.67 seconds
1mS timer:set time 0.001~32.767 seconds
with interruption accuracy timer
 
Counter (C)
Points
635 Points
Specification
16 bits counter:Set value K0~32767
32 bits counter:Set value K0~2147483647
Data Register (D)
5000 characters
FlashROM Register (FD)
64 characters
Expansion Internal Register (ED)
36864 characters
High-speed Count Format
High speed counter, pulse output, exterior interruption
Timing Scanning Interval Setting
1~99mS
Password Protection
6 characters ASCII
Self-diagnose Function
Power on self-diagnose, monitor timer, grammar check
 
General Specifications
Item
Specification
Program Operation Mode
Circulation scanning mode, timing scanning mode
Program Mode
Instructions and ladder chart
Dispose Speed
0.5us
Power Failure Holding
FlashROM
User Program's Capacity
8000 steps
I/O Points
18 input points, 14 output points
Output Format
Relay
Power Supply
AC220V
Interior Coil's Points (M)
8512 points
 
Timer (T)
Points
620 points
Specification
100mS timer:set time 0.1~3276.7 seconds
10mS timer:set time 0.01~327.67 seconds
1mS timer:set time 0.001~32.767 seconds
 
Counter (C)
Points
635 Points
Specification
16 bits counter:Set value K0~32767
32 bits counter:Set value K0~2147483647
Data Register (D)
8512 characters
FlashROM Register (FD)
2048 characters
High-speed Count Format
High speed counter, pulse output, exterior interruption
Timing Scanning Interval Setting
1~99mS
Password Protection
6 characters ASCII
Self-diagnose Function
Power on self-diagnose, monitor timer, grammar check

 